Mileage
139,405
Service Date
5/30/2023
Services Performed
- Service air conditioner. Check condition of all belts and lines. Test system performance. Inspected A/C, Blower, mode and temperature controls are working. Ambient temp 81°F Static pressure 80PSI vent temp 95°F low side 0 PSI High side 100 PSI Finding system to be low on charge. See no visible leaks. Compressor is covered with oil and coolant unable to determine is any A/C oil is present. Recommend repair coolant leak (water pump). Evacuate and recharge to capacity. Clean Compressor and monitor.
- EVACUATE AND RECHARGE A/C SYSTEM Evacuated and recharged to capacity. Low 28 PSI high 215 PSI Ambient 81° Vent 42°
- WATER PUMP – Remove & Replace – FWD – [Includes: R&I Camshaft Drive Chain.]
BRIAN S. gave our service a 5 star review on 5/31/2023